R.T. Quality Assurance
  • Robert Lustig, MD
  • Betty Martin, Director
  • Lorraine Quarles, Senior Dosimetrist
  • Denise Manfredi
  • Nancy Linnemann
  • Julie McIlvaine
  • Joanne Hunter
  • Tammy McGlade, Administrative Assistant
2
R.T. Quality Assurance
  • The RTQA staff is responsible for coordinating the review process for the radiation treatments delivered on protocol studies. The two step process involves
    • Initial Review- QA Radiation Oncologist and dosimetrist
    • Final Review- Study Chair and dosimetrist
3

Studies with Initial Review
  • The purpose of the Initial review is to identify any protocol violations and notify the institution early enough in the treatment so corrections can be made.
  • QA radiation oncologist and dosimetrist  review the initial data requested in section 12 that is due within 1 week of the start of RT
4
Data submission requirements for studies with Initial Review
  •  T2 Form
  • Prospective information about the planned radiation treatment
  • This shows us that the treating physician has interpreted the protocol correctly
  • Planned total dose must be filled in on the form


5
T3
Simulation Film
  • This is an example of a Simulation Film. They will have field shaping drawn on them with a wax pencil. These show what the physician intends to treat.


6
T3
  • This is a Digitally Reconstructed Radiograph (DRR). These are replacing Simulation films.
  • This is done on a computer, the Physician does the field shaping from the CT plan.
7
T3
Port film
  • This is an example of a port film on hard film.
  • These films show what will actually be treated.
  • At the review these are compared to the sim/ DRR.
8
T3
  • This is a Portal image captured digitally.
  • These will be printed out on paper.
  • Please do not put label over field identifiers
9
T4/ TL Forms
On older studies
  •    These forms no longer have to be filled out
10
T4/TL
Computer dose calculation data
11
To Summarize:
 data submission for
studies with Initial review
  • Data to be submitted to RTQA Dept. within one week of start of radiation treatment:


  • T2 - Protocol treatment form
  • T3 - Initial simulation/DRR’s & portal Images
  • T4 - Computer generated dose calculation data
12
Transmittal Form
  • The Dosimetry transmittal form should be used when RT data is sent to RTOG headquarters.  This does not replace  identifying films with the appropriate labels.
  • Also submit this form to suppress RT data
13
Submitting the data
  • If you submit multiple cases together, they must be separated from each other with clips
  • Please do not staple different coded data together.
  • Put a label on each film, each paper. Do not put label over field name
  • Label template available on our website
14
When all the Initial Data is received what happens?
  • Makes sure field borders match protocol specification.(T3)
  • Compares films to ensure what is planned to be treated will actually be treated (T3).
  • Verifies doses on T2 match Section 6 in protocol.
  • Reviews the treatment plan(T4) for protocol compliance.
15
Z2 Form
  • The Z2 form is a request for additional initial dosimetry information.  This request is generated after the radiation oncologist has reviewed the case and determines that additional data is necessary to complete the initial review process.
  • When sending additional dosimetry data attach a copy of the Z2 form to ensure appropriate credit.


16
Initial review: “Deviation”
 Memorandum (Blue)
  • RTQA Rad Onc has found a variation in RT data submitted with the protocol parameters.
  • Still submit the final RT data
17
Initial review: “Deviation”
 Memorandum (yellow)
  • This memorandum  means it is too late for changes in treatment to be made.
  • Still submit the final RT data
18
R. T. Quality Assurance
Final Review
  • Study Chair evaluation of entire course of Radiation Therapy after all required data has been received at Headquarters
  • Determine if each patient’s treatment was delivered according to protocol
  • Scores are given for total dose delivered, field borders, dose fractionation, and total elapsed days of treatment
19
Data Collection
Section 12
20
For IMRT/ 3D-CRT studies
 Section 12.2 -12.2.1 are your guidelines for submission
  • 12.2 Summary of Dosimetry Data Submission for 3DCRT and IMRT
  • Submit to ITC; see Section 12.2.1
  • Item Due
  • Preliminary Dosimetry Information Within 1 week of start of RT


  • 􀂃 Digital Data Submission Form (DDSI)
  • 􀂃 CT data, critical normal structures, all GTV, CTV, and PTV contours
  • 􀂃 Simulation films and/or digital film images for all initial treatment fields and orthogonal set up pair
  • 􀂃 First day port films (or digital images) of all initial treatment fields and orthogonal set up pair
  • 􀂃 Digital beam geometry for initial and boost beam sets
  • 􀂃 Doses for initial and boost sets of concurrent treated beams
  • 􀂃 Digital DVH data for all required critical normal structures, GTV, CTV, and PTVs for total dose plan
  • 􀂃 Hard copy color isodose distributions for total dose plan as described in QA guidelines
  •  Item Due
  • Final Dosimetry Information Within 1 week of RT end


  • 􀂃 Radiotherapy Form (T1) [copy to HQ and ITC]
  • 􀂃 Daily Treatment Record
  • 􀂃 Simulation films and/or digital film images (or digital images) of all boost treatment fields and orthogonal set up pair
  • 􀂃 First day port films of all boost treatment fields and orthogonal set up pair
  • 􀂃 Modified digital patient data as required through consultation with Image Guided Therapy QA Center



  • 12.2.1 Digital Data Submission to ITC
  •  Digital data submission may be accomplished using magnetic tape or the Internet. For network submission: The FTP account assigned to the submitting institution by the ITC shall be used, and e-mail identifying the data set(s) being submitted shall be sent to: itc@castor.wustl.edu For tape submission: Please contact the ITC about acceptable tape types and formats. Hardcopies accompanying digital data should be sent by mail or Federal Express and should be addressed to:
  • Image-Guided Therapy Center (ITC) ATTN: Roxana Haynes 4511 Forest Park, Suite 200 St. Louis, MO 63108
  •  314-747-5415 FAX 314-747-5423
21
Patient Calendar
22
RTQA Final Review
Data Submission
  • Due within one week of completion of Radiation Treatment:
  • T1 – Radiotherapy Form
  • T5 – RT Treatment Record/Daily Chart
  • T6 – Summated isodose distribution
  • T7 – Electron field documentation
  • T8/TP – Simulation or DRR’s/Portal images of all Cone Down or Boost fields
  • TL – Computer dose calculation data
  • DV – Dose Volume Histogram
23
T1    Radiotherapy Form
  • T1 form is submitted after RT has been completed
  • Total dose must reflect exact amount of radiation patient received
24
T5
25
T6
26
T7
  • Acceptable electron  field documentation includes:
  • Portal images
  • Simulation or DRR images with fields delineated
  • Photos with fields delineated
  • Anatomical diagrams with fields delineated
27
  T3    T8
28
  T3    T8
29
DV (Dose Volume Histogram)
30
Z4 Form
  • RTQA Form requesting additional data to complete preparation for final review by Study Chair
  • Requires a prompt response
31
RTQA Contacts

  • Betty Martin (215) 574-3209
  • Lorraine Quarles (215) 574-3181
  • Denise Manfredi (215) 717-2755
  • Nancy Linnemann (215) 717-0853
  • Julie McIlvaine (215) 574-3229
  • Joanne Hunter (215) 574-3222
  • Tammy McGlade (215) 574-3219
  • Administrative Assistant